Posted April 30, 2020

Performance-based Alternative Solutions the Key to Cheaper Cladding Replacement Costs

green plant on brown round coins
Bodies corporate need not despair when served with an Order or Notice from the Municipal Building Surveyor or from the Victorian Building Authority (VBA).

There may literally be a “deemed to satisfy” solution available for some buildings, meaning that not all of the cladding installed on the façade of a building might need to be removed.

In November last year, a mixed-use building in Docklands was approved by the Building Appeals Board (BAB) to implement an alternative solution designed by their consultant fire engineer, which would have the effect of permitting some of the combustible material installed on the façade to remain on the building, provided that sufficient non-combustible material could be installed around the façade to act as a fire break, together with the installation of sprinklers on the façade.

This caused the repair costs to drop by over 80 per cent, which is a great outcome for the body corporate.

This decision was followed up by another case in March of this year for an apartment complex of 21 units in Carnegie.

The BAB ruled that the prescriptive deemed to satisfy the test for compliance of combustible cladding, such as expanded polystyrene (EPS) panelling, could be sidestepped if the performance requirements in CP2 and CP4 of the Building Code were satisfied, and if the holistic fire safety situation of the overall building otherwise resulted in a satisfactory level of safety.

In April 2019, the body corporate lodged an application with the BAB seeking a determination under s160A of the Building Act 1993.  The determination sought was that the design or construction of the building complied with the performance requirements CP2 and CP4 of the Building Code, as an alternative path to compliance.

Combustible EPS cladding had been installed only on the upper two levels of the building and on external walls on balconies, but with no combustible cladding on the ground level.  In addition, there was an eyebrow/canopy on the top-most level consisting of combustible aluminium composite panelling (ACP), set back some distance from the edge of the building.

With regards to other fire safety features at the premises, there was sprinkler protection that covered the entire building including the basement. Also, each level containing residential units was supplied with an internal fire hydrant set in an enclosed fire isolated cupboard, plus an external fire hydrant set back from any flammable cladding by a distance of more than three metres.

Instead, the Board stated that the assessment of fire risk for a building is “an integrated assessment which is not automatically determined from a single variable.” Therefore, the probability of ignition was just one factor to consider when deciding the level of risk for the building as a whole.

Furthermore, the Board found the ACP lining on the eave to the top storey “to be of minor consequence to the level of fire safety in the building” and did not rule that any of it had to be removed.

In summary

The board determined that the EPS panels and ACP installed as external cladding complied with performance requirements CP2 and CP4 of the Building Code and ordered the owners to complete some further remedial work measures recommended by the building’s fire engineer to improve the building’s overall safety further.

In our view, any body corporate served with a Notice or Order for the removal of cladding should first engage a well-regarded fire safety engineer to get a second opinion as to whether all of the combustible cladding material needs to be removed or whether there are “holistic” alternatives that can still comply with the BCA.

Written by
Change Body Corporate
The contents of this article or website are only intended to provide a general overview of the topics discussed. The author of this article makes no representations as to the accuracy or completeness of any information and the information is not intended to constitute investment, legal or professional advice. You should seek professional advice before acting or relying on any of the content. This article does not contain references to any specific company, organisation or individual, unless expressly specified.
Still looking for answers your manager should be giving you?
We help Committees of 10+ lot buildings who are tired of being left in the dark. Tell us what’s going on, and we’ll help you move forward.

    Please note: Our services are exclusively for Committees of buildings with 10 lots or more.

    Aug 24, 2015 Laws & Regulations

    Long Overdue Review Of Consumer Property Acts

    Media Release 21-8-2015, the Minister for Consumer Affairs, Gaming and Liquor Regulation. The Andrews Labor Government has announced a sweeping review of outdated laws covering estate agents, land sales, conveyancing…

    Dec 4, 2019 Laws & Regulations

    Embedded Networks Victoria: Are You Overpaying for Electricity?

    Victorian Apartment Owners Stuck in Costly Embedded Networks A new study by the Victoria Energy Policy Centre has found that customers in apartment buildings in Victoria on embedded networks are…

    Aug 13, 2020 Laws & Regulations

    James v Christou (Building and Property) [2020] VCAT 563

    Background This proceeding concerned two lots in an apartment complex. One was owned by the Applicant (Mrs James), and the other by the Respondent (Mrs Christou). They were adjoining neighbours…

    Sep 25, 2016 Laws & Regulations

    Body Corporates Cannot Prohibit Use of Short Term Letting of Apartments

    Bodies Corporate In July 2016, The Supreme Court of Victoria handed down an important decision in Owners Corporation PS 501391P v Balcombe [2016] VSC 384 (Balcombe case) regarding whether a…